Menu

nSens-HT-CSP (with protective filters)

Capacitive measurement technology for comfort air conditioning

Digital humidity & temperature sensor with capacitive humidity sensor.

CSP sensor with nCap-P (with protective filter)

The adjustment points are stored directly in the sensor.
The sensor is pluggable and can be exchanged very quickly and easily.

Separate calibration/adjustment kit with software available.

  • Calibration and identification data stored directly in the sensor
  • Automatic sensor recognition
  • Versatile connection options

nSens - Cable Extension

260 1136 Cable extension 5m
260 1201 Cable extension 2mCable 3*0.5mm2, very resistant, halogen-free and with
2 quick couplings.
with each:
– 1 plug for nSens-HT / nSens-T sensor
– 1 plug to nSens cable Cable plug

 

Trigger the fancybox

nLink-Modb-2016 nLink-Modbus (RTU/RS485) Adapter

Communication adapter for all nSens sensors on Modbus
RTU, RS485.
Power supply 5-12VDC.
Attention: each nSens sensor is connected to a 1 nLink-Modbus
is required for connection.

Technical data:

Dimension: 20*60mm
Power supply: 5-12V DC
Outputs: Modbus RTU

Modbus allows the reading of all climate and diagnostic data of the connected nSens sensors.

Technical description / Modbus register on novasina.ch

Configuration of the adapter via Modbus or nCom485 set (260 1125).

Spec Sheet

 

Trigger the fancybox

nSens Cable for Modbus

2600872

To connect the nLink-Modbus adapter to the Modbus network

  • Adapter side with M12 screw connector
  • Network side with 4 open cable ends

 

Trigger the fancybox

nSens Extension for Duct Mounting

Compatible with all nSens sensors and nSens cables. 

Trigger the fancybox

nLink-UMB Adapter to nSens (HT/T)

2601063

Conversion adapter from nSens sensor to bus input of the ClimMate.

Attention : for each nSens sensor 1 nLink-UMB is required for connection.

Trigger the fancybox

Wall and Duct Mounting Kit

Set for mounting nSens sensors on walls or channels, incl. screws.
The duct flange seals up to a pressure of 3 bar!
Trigger the fancybox

Wall Mounting Kit

2601165
For wall distance up to center 20mm for different sensor types.
Wall fixing material is included in delivery
Trigger the fancybox

nSoft-CAL Calibration Set

2601094

Windows based software for calibration and adjustment of nSens probes on the PC. Runs on Windows 98/2000/XP/Vista/Windows 7 and 8.

Set includes

  • 1 nlink USB cable (1.8m) for all nSens sensors – Software adjustment of nSens sensors
Trigger the fancybox

Humidity Generators SAL-SC (with factory certificate)

Ready to use and reusable as often as required when stored correctly.

Shelf life 5 years (with correct storage)

Moisture standards based on saturated salt solutions in plastic cylinders, with moisture-permeable membrane.

Consult the instruction manual of the instrument to see which points can be adjusted. The other SAL-SC can be used for calibration.

MSDS (zip)

Storage

 

Trigger the fancybox

Humidity Generators SAL-SC (with accreditation)

Humidity standards based on saturated salt solutions in plastic cylinders, with moisture-permeable membrane.

Including internationally traceable UKAS certificate.

MSDS (zip)

Storage

Info UKAS

Trigger the fancybox

Humidity Generators in the Case Set

111 7847-Case set with SAL-SC

111 7841-Case without contents

Humidity standards SAL-SC delivered as a set in a case incl. adapter for Novasina sensor systems
The case set contains:
– SAL-SC 11
– SAL-SC 33
– SAL-SC 53
– SAL-SC 75
– SAL-SC 90
– QA Certificate for SAL-SC
– 2 adapters for Novasina sensor systems

 

Trigger the fancybox

Adapter SAL-SC

260 1143 – Adapter SAL-SC/nSens2
60 1271 – Adapter variable 9-17mm

– for all sensor types up to 17mm

Plastic adapter for humidity standards as reduction piece and radial seal on the circumference of the respective sensor.

Trigger the fancybox

Thermal Insulation Box for SAL-SC

1111302

Styrobox for temperature stabilization of a SAL-SC check during adjustment. Box consisting of 2 half shells,

which are mounted around the SAL-SC cylinder.

Trigger the fancybox

SCS Certification 3 Points

SCS or Dakk’s calibration certificate. Verification by an accredited testing laboratory, incl. certificate.
Calibration at 3 humidity points (RH) and 1 temperature point with indication of measurement uncertainty (fixed measurement points)
Individual points can be requested.
Trigger the fancybox

Factory Calibration with ISO 9001 Certificate

Factory certificates for nSens-HT-CSS must be provided if required.

nSens-HT-ENS contain the factory certificate at 5 points (111 2874) in the scope of delivery.

Sensors can be recalibrated and adjusted at any time.

Trigger the fancybox
Questions 

Thank you for your interest in our products.

Do you have questions or concerns about the applications or the product?

Please use our contact form to contact us. We will deal with your request as soon as possible and get back to you by mail or phone.